Skip directly to the content

Up to 15% off + Liroma donates €10 per order to KWF for Pink Ribbon 

Certificates and test reports
4.7/5 (1000+ reviews)

Certificates and test reports

  • Independently measured in an American light laboratory

Independently measured

Measured by LightLab International in the United States

In October 2026 the PrimeFORCE Gen5 series was measured by LightLab International in Allentown, Pennsylvania: an independent laboratory for light measurement. All PrimeFORCE panels use the same eight LEDs and the same driver. We supplied a panel from the series; the measurement, the equipment and the report are the lab’s own.

Laboratory
LightLab International, USA
Series
PrimeFORCE Gen5
Test date
October 15, 2026
Report number
LLIA003091-001
  • 8 of 8wavelengths verified, each within 7 nm of the specification
  • 87%of the measurement area above 20 mW/cm² at 15 cm
  • 86%of the intensity at the centre is retained from 15 to 45 cm

Our figure, and how to compare it

Many brands publish a figure from a solar meter. That kind of meter is made for sunlight and reads the narrow red and near infrared of LEDs too high: for this panel, three times too high. So this page shows what the lab measured first, and next to it what the same lamp reads on a solar meter. That way you can compare us with any other brand on the same basis.

Our figure

Spectroradiometer, LightLab

66,6mW/cm²

centre of the panel, at 15 cm

A spectroradiometer splits the light by wavelength and only adds up what is actually emitted, from 350 to 1700 nm. This is the method laboratories use. The figure is lower, but you can put it next to any other lab report.

Measured with two calibrated Gigahertz-Optik BTS2048 meters, after the panel had reached operating temperature in line with IES LM-79.

For comparison

The same lamp on a solar meter

207,3mW/cm²

centre of the panel, at 15 cm

Measured with a Sanpo SM206: the type of meter behind most figures of 150 to 200 mW/cm² in this market. If you see a figure like that from another brand, put it next to this figure, not next to our lab figure. Every measurement was photographed with the display and the distance in view.

Solarmeter onder de PrimeFORCE Elite G5-300 op 15 cm, display toont 207,3 mW/cm²
15 cm
Solarmeter onder de PrimeFORCE Elite G5-300 op 25 cm, display toont 184,3 mW/cm²
25 cm
Solarmeter onder de PrimeFORCE Elite G5-300 op 30 cm, display toont 182,7 mW/cm²
30 cm
Solarmeter onder de PrimeFORCE Elite G5-300 op 45 cm, display toont 170,6 mW/cm²
45 cm

How the light falls

LightLab measured the light at 481 points, every 2.5 cm, across an area of 30 by 91 cm under the panel. The darker the square, the more light. Choose a distance.

075
Centre of the panel
66,6mW/cm²
Average across the area
49,7mW/cm²
Dose in 10 minutes
29,8J/cm²
Share of the area above 20 mW/cm²
87%
075
Centre of the panel
60,4mW/cm²
Average across the area
43,6mW/cm²
Dose in 10 minutes
26,1J/cm²
Share of the area above 20 mW/cm²
84%
075
Centre of the panel
57,3mW/cm²
Average across the area
39,0mW/cm²
Dose in 10 minutes
23,4J/cm²
Share of the area above 20 mW/cm²
88%

The dose is the average multiplied by 600 seconds, divided by 1000. At 45 cm the light covers a larger part of the area than at 15 cm: further away the intensity is lower, but more even.

At three distances

Both meters side by side, at the same three distances.

Distance Solar meter, centre LightLab, centre LightLab, average across the area Dose in 10 minutes (J/cm²)
15 cm 207,3 66,6 49,7 29,8
30 cm 182,7 60,4 43,6 26,1
45 cm 170,6 57,3 39,0 23,4

All values in mW/cm², with red and near infrared on at the same time. The centre is always higher than the average, because the edges of the measurement area extend beyond the panel.

Every wavelength verified

LightLab measured each of the eight LED types separately. The large number is the measured peak, the small one the specified wavelength.

634 nmspecified 630
651 nmspecified 650
661 nmspecified 660
677 nmspecified 670
809 nmspecified 810
833 nmspecified 830
857 nmspecified 850
1061 nmspecified 1060

Unit measured: PrimeFORCE Elite G5-300. The other panels in the series have the same LEDs and driver, but were not measured individually; intensity may differ slightly by panel size. The lab did not select the unit itself. The report is a measurement and not a certification or approval by NVLAP, NIST or any US government agency.

Certifications for the PrimeFORCE Gen5

Tested by an independent body and officially issued in Liroma’s name, in accordance with the applicable European directives.

Many suppliers display CE documents from their manufacturer or supplier. Liroma PrimeFORCE’s certifications have been independently tested and verified by external testing bodies in accordance with the applicable EU directives and officially issued in Liroma’s name.

CE LVD Certification

Low Voltage Directive 2014/35/EU

FCS202608021CA02

Tested to EN 60335-2-23 in conjunction with EN 60335-1 and EN 62233. Covers the Compact G5-100, Advanced G5-200, Elite G5-300, Multi G5-500, Max G5-600 and Ultra G5-1000. Issued on 27 August 2026 by Dongguan Funas Testing Technology.

Download certificate

CE EMC Certification

EMC Directive 2014/30/EU

FCS202608021CA01

Tested to EN IEC 55014-1 and EN IEC 55014-2 for both emission and immunity. Covers the same six Gen5 models. Issued on 27 August 2026 by Dongguan Funas Testing Technology.

Download certificate

EU Declaration of Conformity

EU Declaration of Conformity

Prepared under Liroma’s own responsibility and signed on July 29, 2026. Refers to the LVD and EMC test reports and covers the Compact G5-100, Advanced G5-200, Elite G5-300, Max G5-600, and Ultra G5-1000.

Download certificate

RoHS Certification

RoHS Directive 2011/65/EU and (EU) 2015/863

RC2608116189

Assessed under EN IEC 63000:2018 for heavy metals and phthalates, both compliant. Covers the Compact G5-100, Advanced G5-200, Elite G5-300, Multi G5-500, Max G5-600 and Ultra G5-1000. Issued on August 18, 2026 by South China Technical Service.

Download certificate
4,7/5 1000+ reviews Trustpilot

More than 41,000 people came before you!

Tested standards

CE LVD

  • EN 60335-2-23:2003 + A1:2008 + A11:2010 + AC:2012 + A2:2015
  • EN 60335-1:2012 + A11:2014 + A13:2017 + A1:2019 + A14:2019 + A2:2019 + A15:2021
  • EN 62233:2008 + AC:2008

These standards apply to household appliances for skin and hair care. They cover safe construction, insulation and use between 100V and 240V, plus exposure to electromagnetic fields.

CE EMC

  • EN IEC 55014-1:2021
  • EN IEC 55014-2:2021

These standards ensure the device does not interfere with other equipment and is itself resistant to electromagnetic influences.

RoHS

  • EN IEC 63000:2018
  • Directive 2011/65/EU
  • Delegated Directive (EU) 2015/863

These standards restrict the use of hazardous substances such as lead, mercury and cadmium in electronics. Tested for heavy metals and phthalates.

Would you like to know how it works?

What red and near-infrared light do in your cells, and why wavelength and distance matter.

How does red light therapy work?

4,7/5 1000+ reviews Trustpilot

Certificates and test reports

CE LVD certificate Gen5

Low Voltage Directive 2014/35/EU, certificate number FCS202608021CA02, issued 27 August 2026.

PDF Download

CE EMC certificate Gen5

EMC Directive 2014/30/EU, certificate number FCS202608021CA01, issued 27 August 2026.

PDF Download

EU Declaration of Conformity

Signed on July 29, 2026, with reference to the LVD and EMC test reports.

PDF Download

Solar meter report PrimeFORCE G5

Measured irradiance per model at four distances, including method and instruments. Liroma's own measurement, August 2026.

PDF Download

LightLab International test report

Irradiance at 15, 30 and 45 cm and measured peak wavelength per LED, PrimeFORCE Gen5 series (unit measured: Elite G5-300). Report LLIA003091-001, tested October 15, 2026.

PDF Download

RoHS certificate Gen5

Directive 2011/65/EU and Amendment (EU) 2015/863, assessed in accordance with EN IEC 63000:2018. Certificate number RC2608116189, issued on 18 August 2026 by South China Technical Service.

PDF Download

View the PrimeFORCE Gen5

Six panels, from compact to full-body. All with the same eight wavelengths.

All products

Frequently asked questions

Just one more thing

Why are there two different figures for the same lamp?

Because two kinds of meter were used. A solar meter reads 207 mW/cm² at 15 cm, LightLab’s spectroradiometer 66.6. The solar meter is made for sunlight and reads higher with LEDs. Most brands only publish the solar meter figure. We show both, so you can compare us with any other brand, however they measured.

Are the PrimeFORCE Gen5 panels CE certified?

Yes. The Gen5 series was tested under the Low Voltage Directive 2014/35/EU and the EMC Directive 2014/30/EU. The certificates bear the numbers FCS202608021CA02 and FCS202608021CA01 and were issued on August 27, 2026.

Have the certifications been independently tested?

Yes. The CE certificates were issued by Dongguan Funas Testing Technology. Irradiance and wavelengths were measured by LightLab International in the United States, an independent light laboratory. The solar meter report is our own measurement. Each document states who carried out the measurement.

Are the certificates in Liroma’s name?

Yes. Liroma Red Light Therapy, part of Triple A bv, is listed as both the manufacturer and the holder on both certificates. There is no supplier in between.

What does CE LVD mean?

The Low Voltage Directive 2014/35/EU. The Gen5 has been tested according to EN 60335-2-23, the standard for household appliances for skin and hair care, in conjunction with EN 60335-1 and EN 62233.

What does CE EMC mean?

The Electromagnetic Compatibility Directive 2014/30/EU. Tested according to EN IEC 55014-1 and EN IEC 55014-2: both what the device emits and what it must itself be resistant to.

Which models are covered by the certificates?

The Compact G5-100, Advanced G5-200, Elite G5-300, Multi G5-500, Max G5-600, and Ultra G5-1000. The Elite has been physically tested; the other models share the same circuit board and construction.

Which wavelengths were measured?

All eight, and they are in every PrimeFORCE panel. LightLab measured each LED separately: 630 nm peaks at 634, 650 at 651, 660 at 661, 670 at 677, 810 at 809, 830 at 833, 850 at 857 and 1060 at 1061 nm.

Can I download the documents?

Yes, everything on this page can be downloaded freely: the LightLab test report, both CE certificates, the RoHS certificate, the EU Declaration of Conformity and the solar meter report. We provide the full CE test reports to authorities on request.

Shopping cart

4,7/5 1000+ reviews
Up to 15% off + Liroma donates €10

Your shopping cart is currently empty.

60-day trial Free treatment schedule Up to 3 years’ warranty